Flexible cords to bs 6500 net of copper insulated with pvc core a for 0. Ducab product range covers high voltage cables up to 400kv, ducab. Secure pdf files include digital rights management drm software. Suitable for internalexternal applications and direct burial. Cy control cable, sy control cable, yy control cable, flexible cord manufactured to bs en 50525211 used in production lines, lighting intallations, portable tools and conveyors. Pvc insulated, nonarmoured cables for voltages up to and including 450750v, for electric power, lighting and internal wiring bs 6007. Bs 6724 armoured lshf power cable technical datasheet construction conductor material. Cable trunking specification for cable trunking made of insulating material. British standards power cable standards batt cables. Rubber or silicone rubber insulated flexible cables and cords for coil end leads bs 62073. Pvc insulated, nonarmoured cables for voltages up to and including 4501750v, for electric power, lighting and internal wiring.
Bs 6004 round pvc insulated, pvc sheathed cable, 300500 v, single core, in accordance with bs 6004 application the cable is designed for electricity supply, lightning, and electrical installations. The cable is designed for electricity supply, lightning, and electrical installations. Designed to be a highly user friendly, high performance fire resistant cable, nexans alsecure nx200 is fully lul. Rohs trusted kitemark km 634267 318a bs 6004 arctic grade cable eland product group. Drm is included at the request of the publisher, as it helps them protect their by restricting file sharing.
The cable features plain annealed copper conductors, two cores laid flat and an uninsulated circuit protective conductor in pvc insulation and a grey pvc outer sheath. The above wiring cables conform to bs 6004 specification for pvc insulated cables nonarmoured for electric power and lighting. British standard electric cables pvc insulated, non armoured. Quality and safety are the hallmarks of our diverse range of products, which are designed and manufactured to the very highest standards such as iso 9001 and approved by the leading approvals organisations nationally and internationally including basec, lpcb and lloyds. Connection units are intended for use with cables conforming to bs 6004. Alibaba manufacturer directory suppliers, manufacturers. All bsi british standards available online in electronic and print formats. Suitable for laying in conduit or trunking where mechanical. Multicore low voltage power and control cable that features cross linked insulation, heavy galvanised steel wire armour and black uv stable lshf jacket.
Ss3583, iec602273, bs en 50525231 operating temperature. This standard, like bs 76291 above, details all material types, the physical dimensions such as conductor material and sizes, minimum insulation and sheath thickness. Pvc insulated, nonarmoured cables for voltages up to and including 450750 v, for electric power, lighting and internal wiring. Fixed wiring cable bs 6004 624y twin and earth pvc cable technicalspecication 1 of 3 application domestic wiring cable. Connection units with cable outlets are additionally intended for use with flexible cables, conforming to the relevant part of bs en 50525 see annex g, on the load output side. Electric cables low voltage energy cables of rated voltages. Fixed wiring cable 6181y bs 6004 cable technicalspecification 1 of 4 issue no 01032014 cable standards bs 6004, bs eniec 6033212 application fixed installation in dry or damp areas for domestic and light industrial wiring. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where the risk of. Pvc insulated non sheathed single core heat resisting cable for internal wiring construction conductors. Bs7211 cables fixed wiring cable 6491y, 6181b, 6491b, twin and earth lszh cable fixed wiring cables are generally used for power distribution, indoor and outdoor installations and certain ranges have added impact protection due to their steel wired armouring or aluminium wired armouring. Our cabling assembly house cah, located in the heart of harleysville, pa, is known throughout the industry for our. Plain annealed copper, pvc insulated cable insulation colour. Low voltage energy cables of rated voltages up to and including 450750 v u0u.
The cables are mainly used in power stations, mass transit underground passenger systems, airports, petrochemical plants, hotels, hospitals, and highrise buildings. Bs en 50525231 bs 6004 conductor operating temperature. Pvc insulated and pvc sheathed cables for voltages up to and including 300500 v, for electric power and lighting bs en 505251. Fixed wiring cable 6491x h07vr h07vu bs en 50525231 cable technicalspecification 1 of 5 issue no 0103 2014 cable standards bs en 50525231 previously bs 6004 basec approved, bs eniec 6033212 application 6491x cable h07vrh07vu is suitable for power and lighting circuits and building wiring. Reduced circuit protective conductor size is permitted i. Can be installed in fixed installations in dry or damp premises clipped to surface, on trays or in free air where the risk of mechanical damage would not be an issue. Pvc insulated, nonarmoured cables for voltages up to and including 450750v, for electric power, lighting and internal wiring. Abstract gives requirements for the construction, test methods and performance of cables with polyvinyl chloride pvc insulation of.
Bs 6004 and bs 7211 were reissued in september 2012. British standards electrical cable telephone cable. The company environmental manual outlines the objectives, procedures and tools. This british standard is the uk implementation of en 50525231. Nonarmoured cables to bs 6004 or bs 7211 bs 6004 covers pvcinsulated, nonarmoured cables for voltages up to and including 450750 v, for power and lighting. These cables are designed for dc power supplies on telecom equipment and power applications where flexibility is required. Pvc insulated and pvc sheathed cables for voltages up to and including. Pvc insulated and sheathed, single core, flat twin and flat three core cables with bare cpc to bs 6004 conductors are class 2 stranded except where shown. Electric cables low voltage energy cables of rated. Nexans alsecure nx200 nexans, the worldwide cable manufacturer has added alsecure nx200 fire resistant cable to its wide range of cables. Thermosetting insulated, armoured cables for voltages of 600v and 19003300v bs 6004. Industrial cablesbritish standard 2491x to bs 6004new bs en 50525231 application and description. H05v2u, h05v2r, h05v2k 300500 v pvc insulated non sheathed single core cables for internal wiring norm. Bs 7211 covers similar cables having thermosetting insulation with low emission of smoke and corrosive gases when affected by fire.
Glossary of electrotechnical, power, telecommunication, electronics, lighting and colour terms. Ms 21125, bs 6500, iec 602275 portable socketoutlet, household appliances, audiovideo products housing cables up to 750v ms 21121 to ms 21126, bs 6004 fixed wiring and lighting pvc insulated 600v to 1 kv ms 2100 to ms 2111, bs 6346 low voltage electricity supply xlpe insulated from 1 kv to 3 kv iec 605021 low voltage electricity supply. Prysmian guide to changes of british standard numbers en. Astm b230, astm b231, bs 215 part 1 aluminum conductor steel reinforced a sr astm b232b498, bs 215part 24565, iec 209 pv insulated and sheathed able bs 634667466004, vde 02710250 pv insulated able astm d734, bs 600420046485, vde 0250, ul 6283 rosslinked pe insulated power cable 0. A5a cables are tested and accredited by basec, the british. This cable meets the requirements of the low voltage directive 201435eu and the rohs directive 201165eu. In order to read a secure pdf, you will need to install the fileopen plugin on your computer. You have clicked a page that seems to be very popular. Solid or stranded conductor is made from annealed copper wires. Characteristics voltage rating uou 300500v temperature rating fixed. Plain annealed opper lass 1 or 2 to s en 60228 insulation.
Conductors are class 2 stranded except where shown. Rohs compliance has been tested and confirmed by the cable lab trusted kitemark tm. Bs7211 fixed wiring cables twin and earth cable lszh. Bs 6004 flat pvc insulated, pvc sheathed cable with circuit. The cables also generally satisfy the international specification iec 60227 6491 x only. For current ratings refer to table 4d1 of s7671 iee. Bs 7846 is the design, manufacture and test manual for cable makers to provide fire resistant power cables for use in emergency building services.
Bs 6004 624y twin and earth pvc cable eland cables. In fact, its why we like to say that were relentless until a solution is found. Singlecore general purpose cable for use in conduit and trunking. Bs 6004 and bs 7211 now cover only selected uk cables designs and will now include arctic flexible cords.